The WANLIN-340 Wireless Heat Detector with Rate-of-Rise and Fixed Temperature Element ships with these headline parameters: alarm threshold fixed temperature 54-70 deg c by class, rate-of-rise trip between 3 and 30 deg c/min, accuracy class en 54-5 and gb 4716 class accuracy, thermistor tolerance +/-1.5 deg c, rate-of-rise window selectable in three bands, response time static response within 30-120 s to the en 54-5 test regime by class, rate-of-rise trip within 60 s of a fast transient, power supply 3.6v er18505m lithium cell, 5-year service life, field-replaceable, 3-year life on the 4g sku drawing 11 ua standby, 120 ma peak transmit, 28 ma in alarm, output 433 mhz fsk uplink to the 860 panel or the 868d gateway with a 24 h supervisory heartbeat, coverage up to 50 m2 at 6 m mounting height, 30 m2 in high-ceiling or high-airflow areas, alarm output integral 80 db(a) at 3 m sounder plus platform alert and group alarm through the paired gateway, ip65 sealed polycarbonate housing for wash-down kitchens and food plants enclosure, -30 deg c to +70 deg c industrial wide-temp for cold stores, kilns and unheated plant operating range and 100 mm diameter x 46 mm height, 152 g net including the cell. As of September 22, 2026, Wanlin Group (Shenzhen, China) officially launches its 2026 carbon monoxide alarm export programme, featuring the WANLIN-340 Wireless Heat Detector with Rate-of-Rise and Fixed Temperature Element as the flagship OEM and ODM component for overseas buyers, cross-border trading companies, landlord portfolio managers, hotel and resort groups, parking and tunnel operators, marina and caravan dealers, HVAC contractors, safety products distributors and regional importers who source CO detection hardware from a China-based source factory under the Wanlin brand. The programme targets importers, tender bidders, housing associations and letting agents, senior living and student housing operators, hotel and hostel chains, retail and fuel forecourt groups, industrial plant owners, data centre and colocation operators, system integrators and wholesale distributors who now buy carbon monoxide protection by the thousand instead of the dozen, and who source it directly from a Chinese manufacturer rather than paying the western brand premium of Kidde, First Alert, BRK, X-Sense, Ei Electronics, Aico, FireAngel, Honeywell, Bosch or Siemens. Wanlin Group as the carbon monoxide alarm supplier, exporter and original manufacturer now opens its doors to global local partners, regional exclusive distributors, overseas cooperation partners and strategic OEM clients across 60+ destination markets.
Core parameters: WANLIN-340 Wireless Heat Detector with Rate-of-Rise and Fixed Temperature Element, rate-of-rise plus fixed temperature dual algorithm evaluated on a thermistor bridge with air-flow compensation. Sensing element ntc thermistor with a stainless-steel heat collector, a1r / a2s / br / cs class selectable per sku. Alarm threshold fixed temperature 54-70 deg c by class, rate-of-rise trip between 3 and 30 deg c/min. Accuracy class en 54-5 and gb 4716 class accuracy, thermistor tolerance +/-1.5 deg c, rate-of-rise window selectable in three bands. Response time static response within 30-120 s to the en 54-5 test regime by class, rate-of-rise trip within 60 s of a fast transient. Power supply 3.6v er18505m lithium cell, 5-year service life, field-replaceable, 3-year life on the 4g sku. Power consumption 11 ua standby, 120 ma peak transmit, 28 ma in alarm. Output signal 433 mhz fsk uplink to the 860 panel or the 868d gateway with a 24 h supervisory heartbeat. Coverage area up to 50 m2 at 6 m mounting height, 30 m2 in high-ceiling or high-airflow areas. Alarm output integral 80 db(a) at 3 m sounder plus platform alert and group alarm through the paired gateway. IP rating ip65 sealed polycarbonate housing for wash-down kitchens and food plants. Operating temperature -30 deg c to +70 deg c industrial wide-temp for cold stores, kilns and unheated plant. Humidity range 10-95% rh non-condensing, conformal-coated pcb on the ip65 sku. Housing material polycarbonate v-0 housing with a 316 stainless-steel heat collector and a gasketed base. Dimensions and weight 100 mm diameter x 46 mm height, 152 g net including the cell. Certifications EN 54-5 / CE / RoHS / REACH / FCC Part 15 / GB 4716 CCCF / IP65 ingress test report. The 2026 carbon monoxide range is built on WANLIN-CO210 sealed 10-year battery CO alarms to EN 50291-1 and EN 50291-2 with UL 2034 documentation on request, WANLIN-CO330 smart LCD CO alarms reporting over Wi-Fi, NB-IoT and 4G LTE Cat-1 with app push, SMS and voice call escalation, WANLIN-CO560 industrial two-stage CO detectors driving garage and tunnel ventilation through relay and Modbus fan control, WANLIN-AIR620 multi-parameter hazard nodes with an electrochemical CO channel, WANLIN-303 combination-class detectors with 433 MHz interconnect, WANLIN-307 and WANLIN-309 IoT detectors on LoRaWAN, NB-IoT, 4G LTE Cat-1 and Wi-Fi, WANLIN-340 rate-of-rise heat detectors in A1R, A2S, BR and CS classes to EN 54-5, WANLIN-222 resettable wireless call points to EN 54-11, WANLIN-656 sounder strobes to EN 54-3 and EN 54-23, WANLIN-860 wireless fire alarm panels to EN 54-2, EN 54-4 and EN 54-21, WANLIN-705 smart electrical fire monitors to GB 14287.2 and GB 14287.3, WANLIN-868D LoRa concentrator gateways with Modbus TCP, MQTT and BACnet IP, WANLIN-770 wireless pressure gauges to EN 837-1, WANLIN-780 wireless level meters to EN 61326, WANLIN-365 combustible gas detectors to EN 50194, WANLIN-260 home fire safety kits, WANLIN-710 Wi-Fi smart circuit breakers to GB 16917 and the A119-YW aerosol test gun and heat detector tester used for commissioning and periodic inspection rounds, shipped with CE, UKCA, UL 2034, FCC, CCCF and SASO documentation packages.
Executive Summary - Wanlin Carbon Monoxide Alarm Portfolio and 2026 Export Programme
Executive summary - 12 buyer-relevant points:
- Flagship model WANLIN-340 Wireless Heat Detector with Rate-of-Rise and Fixed Temperature Element, rate-of-rise plus fixed temperature dual algorithm evaluated on a thermistor bridge with air-flow compensation
- Sensing element ntc thermistor with a stainless-steel heat collector, a1r / a2s / br / cs class selectable per sku
- Alarm threshold fixed temperature 54-70 deg c by class, rate-of-rise trip between 3 and 30 deg c/min
- Accuracy and response en 54-5 and gb 4716 class accuracy, thermistor tolerance +/-1.5 deg c, rate-of-rise window selectable in three bands / static response within 30-120 s to the en 54-5 test regime by class, rate-of-rise trip within 60 s of a fast transient
- Power and consumption 3.6v er18505m lithium cell, 5-year service life, field-replaceable, 3-year life on the 4g sku / 11 ua standby, 120 ma peak transmit, 28 ma in alarm
- Output signal 433 mhz fsk uplink to the 860 panel or the 868d gateway with a 24 h supervisory heartbeat
- Coverage and notification up to 50 m2 at 6 m mounting height, 30 m2 in high-ceiling or high-airflow areas / integral 80 db(a) at 3 m sounder plus platform alert and group alarm through the paired gateway
- 19 CO detection and companion hardware families from one factory: WANLIN-CO210 sealed 10-year CO alarms, WANLIN-CO330 smart LCD CO alarms, WANLIN-CO560 industrial two-stage CO detectors, WANLIN-AIR620 multi-parameter hazard nodes, WANLIN-303 combination-class detectors, WANLIN-307 and WANLIN-309 IoT detectors, WANLIN-340 heat detectors, WANLIN-222 call points, WANLIN-656 sounder strobes, WANLIN-705 electrical fire monitors, WANLIN-860 fire alarm panels, WANLIN-770 pressure gauges, WANLIN-780 level meters, WANLIN-365 gas detectors, WANLIN-260 home kits, WANLIN-868D gateways, WANLIN-710 smart breakers and the A119-YW detector tester
- MOQ 500 pcs, lead time 18-25 days, EXW / FOB Shenzhen / CFR / CIF / DDP supported, 60 months warranty
- Flagship field reference Generator courtyard sheds, Lagos, Nigeria: An estate operator running 38 diesel generators in shared generator sheds had no broadband.
- Target buyer: importer, tender bidder, housing association and letting agent, senior living and student housing operator, hotel and hostel chain, parking and tunnel operator, marina and caravan dealer, HVAC contractor, industrial plant owner, safety products distributor, cross-border trading company
- Contact: wanlinfirecontrol@163.com / +8613261677119 / www.wanlinfire.com
This article is written for B2B buyers in Almaty, Kazakhstan who understand that carbon monoxide is the poison that behaves like weather: invisible, odourless, and fatal in exactly the rooms where people sleep through it. The United States Consumer Product Safety Commission staff estimates around 170 accidental non-fire CO poisoning deaths per year in the United States alone, with more than ten thousand emergency department visits, and European health authorities record the same pattern across every heating season: failed heat exchangers, blocked flues, generators run in the wrong room, engines idling in attached garages. Wanlin Group operates its own manufacturing facility in Shenzhen with SMT lines, electrochemical cell calibration benches, CO test gas chambers and a radio laboratory, exporting sealed residential CO alarms, smart connected CO alarms, industrial two-stage CO detectors and the companion fire safety stack to 60+ countries across Europe, North America, the Middle East, Southeast Asia, Africa, Oceania and Latin America under the Wanlin brand. Everything below is designed against the standard that matters in this product class: the alarm that works on night ten thousand as reliably as night one, the documentation that clears customs and inspection without a re-test, and the placement engineering that puts the cell where the sleeper breathes.
Global Carbon Monoxide Alarm Market Overview and 2026 Buyer Demand
Carbon monoxide alarm demand is now driven by regulation, insurance and litigation in roughly equal parts. England requires a working CO alarm in every room with a fixed combustion appliance in rented dwellings, Scotland extends the duty across the social and private sector, France and Germany impose documented maintenance on the combustion side that increasingly assumes detection on the occupant side, and North American building codes treat listed CO alarms as standard fit in new residential construction. Insurers have followed: portfolio policies in the United Kingdom, hotel groups in Europe and fuel forecourt programmes in the Americas now ask for documented CO monitoring evidence rather than an annual hand-held spot check. The buyers driving it are housing associations and letting agents equipping thousands of rooms, hotel and hostel chains standardising across plant rooms and guest floors, parking and tunnel operators replacing timer-driven ventilation with demand control, caravan and marine dealers factory-fitting alarms that survive salt air and winter storage, and senior living operators who have learned that plain tones do not wake every resident. Contractors, importers and cross-border trading companies supplying Almaty, Kazakhstan increasingly source this layer from China-based original manufacturers like Wanlin, because the landed cost of a Wanlin sealed CO alarm is 40-60% below Kidde, First Alert, BRK, X-Sense, Ei Electronics, Aico or FireAngel retail-chain equivalents at the same EN 50291 or UL 2034 documented scope, and because one factory covers the sealed battery alarm, the smart connected alarm, the industrial fan-control detector and the test tool on a single shipment with one set of declarations.
Market access in Almaty, Kazakhstan is anchored on EAEU TR 043 conformity certificate with the Ministry of Emergency Situations design review. CO alarms, connected detectors, industrial CO detectors, gateways and control panels shipped into Almaty, Kazakhstan clear customs on one HS-coded packing list: the radio type-approval reference, the CE and RoHS declarations, the EN 50291 or UL 2034 type-test reference and the per-unit calibration record travel with the pallet, so the insurer review and the local authority acceptance pass without a second shipment or a re-test at destination, which requires a documented conformity route, a declaration referencing EN 50291-1 or UL 2034 as applicable, a radio type-approval reference for the connected models and third-party approval body involvement where the scheme demands it. Cross-border buyers are advised to verify the declaration, the type-test report and the approval body reference of every device prior to import, since non-compliant or un-certificated CO alarms may be rejected by customs authorities, refused by the insurer, or left out of the compliance file that rental and hotel regulations demand.
Reference: EN 50291-1 and EN 50291-2 for residential carbon monoxide alarms, EN 50292 for placement and application practice, UL 2034 for single and multiple station CO alarms, UL 2075 for system-connected gas and vapour detectors, NFPA 720 and NFPA 72 installation practice, BS EN 50291 for the United Kingdom route, CAN/CSA-6.19 for Canada, GB 15322 for the China scheme, radio type-approval for the 433 MHz, LoRaWAN, NB-IoT, LTE and Wi-Fi models, plus local building, gas safety and workplace requirements in the destination market, United States Consumer Product Safety Commission non-fire CO poisoning estimates, and Wanlin Group 2026 carbon monoxide alarm export programme documentation.
CO Alarm Engineering - Electrochemical Sensing, Time-Weighted Response, Radios and Fan Control
The WANLIN-340 Wireless Heat Detector with Rate-of-Rise and Fixed Temperature Element is engineered inside a four-layer CO detection architecture rather than as an isolated device: (1) a sensing layer built on three-electrode electrochemical CO cells with hydrogen cross-sensitivity compensation, temperature and humidity correction, and an end-of-life prediction model, because the cell is the part that quietly dies first and a dead sensor that still chirps healthy is worse than no sensor; (2) a decision layer applying the time-weighted response envelope of EN 50291-1 or UL 2034 rather than a single instantaneous threshold, plus two-stage industrial logic on the CO560 where the first stage drives ventilation and only the second stage alarms; (3) a transport layer choosing per building between 433 MHz interconnect with no recurring fee, LoRaWAN where hundreds of devices sit behind one gateway, NB-IoT or 4G LTE Cat-1 for dispersed single points, Wi-Fi where the IT department approves it, and RS485 Modbus RTU where the fan controller is the integration point; and (4) an evidence layer holding the ppm curve, the event history, the peak memory and the self-test log, because the insurer, the fire officer and the service contractor all argue less when the data series is attached to the file. Because the package is specified as one design, cell selection, thresholds, transport and evidence format all come from the same document rather than four vendors each protecting their own share of the liability.
Three sub-modules define the engineering depth:
- Sensing front end - NTC thermistor with a stainless-steel heat collector, A1R / A2S / BR / CS class selectable per SKU. Fixed temperature 54-70 deg C by class, rate-of-rise trip between 3 and 30 deg C/min holds the alarm decision across temperature, humidity and contamination drift.
- Power and signal interface - 3.6V ER18505M lithium cell, 5-year service life, field-replaceable, 3-year life on the 4G SKU. 433 MHz FSK uplink to the 860 panel or the 868D gateway with a 24 h supervisory heartbeat plus 11 uA standby, 120 mA peak transmit, 28 mA in alarm covers battery, mains and loop powered builds and every radio from interconnect groups to cellular uplinks.
- Alarm output and enclosure - Integral 80 dB(A) at 3 m sounder plus platform alert and group alarm through the paired gateway. Up to 50 m2 at 6 m mounting height, 30 m2 in high-ceiling or high-airflow areas coverage plus IP65 sealed polycarbonate housing for wash-down kitchens and food plants housing keeps bedrooms, plant rooms, parking decks and marine environments audible, visible and serviceable.
Featured Model - WANLIN-340 Wireless Heat Detector with Rate-of-Rise and Fixed Temperature Element Technical Signature
The featured model is WANLIN-340 Wireless Heat Detector with Rate-of-Rise and Fixed Temperature Element, part of the Wireless Rate-of-Rise and Fixed Temperature Heat Detector (LoRaWAN / 4G / 433 MHz) family, configured as the 433 mhz industrial ip65 build (3 variant). FOB Shenzhen reference price is $17.50 per piece at MOQ 500 pcs, with bulk tier pricing ranging $15.22-$19.43 depending on detection class, measuring range, enclosure rating, output protocol variant, certification scope and packaging artwork. Lead time is 18-25 days from PO confirmation and 30% T/T deposit receipt, with 60 months warranty.
The unique technical signature of WANLIN-340 on this variant combination is documented in the table below. Every parameter listed is engineering-verified by our Shenzhen lab and cross-checked against the applicable EN 50291-1, EN 50291-2, UL 2034, EN 54, ISO 7240 or EN 50194 product standard, the declaration of conformity scope, the radio type-approval and the accuracy and response time requirement of the destination market.
| Specification | Value |
|---|---|
| working_principle | Rate-of-rise plus fixed temperature dual algorithm evaluated on a thermistor bridge with air-flow compensation |
| sensing_element | NTC thermistor with a stainless-steel heat collector, A1R / A2S / BR / CS class selectable per SKU |
| alarm_threshold | Fixed temperature 54-70 deg C by class, rate-of-rise trip between 3 and 30 deg C/min |
| accuracy_class | EN 54-5 and GB 4716 class accuracy, thermistor tolerance +/-1.5 deg C, rate-of-rise window selectable in three bands |
| response_time | Static response within 30-120 s to the EN 54-5 test regime by class, rate-of-rise trip within 60 s of a fast transient |
| power_supply | 3.6V ER18505M lithium cell, 5-year service life, field-replaceable, 3-year life on the 4G SKU |
| power_consumption | 11 uA standby, 120 mA peak transmit, 28 mA in alarm |
| output_signal | 433 MHz FSK uplink to the 860 panel or the 868D gateway with a 24 h supervisory heartbeat |
| coverage_area | Up to 50 m2 at 6 m mounting height, 30 m2 in high-ceiling or high-airflow areas |
| alarm_output | Integral 80 dB(A) at 3 m sounder plus platform alert and group alarm through the paired gateway |
| ip_rating | IP65 sealed polycarbonate housing for wash-down kitchens and food plants |
| operating_temp | -30 deg C to +70 deg C industrial wide-temp for cold stores, kilns and unheated plant |
| humidity_range | 10-95% RH non-condensing, conformal-coated PCB on the IP65 SKU |
| housing_material | Polycarbonate V-0 housing with a 316 stainless-steel heat collector and a gasketed base |
| dimensions_weight | 100 mm diameter x 46 mm height, 152 g net including the cell |
| certifications | EN 54-5 / CE / RoHS / REACH / FCC Part 15 / GB 4716 CCCF / IP65 ingress test report |
Application Scenarios across Homes, Rentals, Hotels, Garages, Vessels and Plant Rooms
Wanlin CO alarms and detectors are protecting sleepers, staff and equipment across six continents: a Manchester housing association, ice-fishing cabins on Lake Winnipeg, liveaboard berths in Auckland, Altbau boiler rooms in Berlin, a parking deck in Turin, generator sheds in Lagos, shisha lounges in Riyadh, ski chalets in Tyrol, gosiwon cubicles in Seoul, a guesthouse in Cusco, karaoke rooms in Ho Chi Minh City, a memory care wing in Toronto, food trucks in Austin, ferry cabins on the Aegean, dormitory towers in Krakow, hotels in Prague, caravans on the Gold Coast, a mine camp in Norrbotten, homes above attached garages in Denver, poultry houses in Limpopo, a colocation compound in Jakarta and hostels in Lisbon. Below are 5 detailed scenarios drawn from those deployments, each with a site, a device count, a transport and integration arrangement, an installation window and a measured or witnessed outcome rather than a capability claim.
Scenario 1: Generator courtyard sheds, Lagos, Nigeria. An estate operator running 38 diesel generators in shared generator sheds had no broadband on site and a landlord liability discussion after a security guard was hospitalised overnight. The CO330 4G LTE Cat-1 variant was chosen because each shed reports by cellular without depending on the estate network, pushing an SMS and voice call to the facility manager at the alarm threshold and a weekly ppm summary to the estate WhatsApp group. Guard rest bunks were moved out of the same room as the generators after the first month of data showed sustained 35 ppm during evening run hours, a level that never reaches an alarm threshold but fails any occupational exposure argument. The estate now logs generator service events against the ppm curve and has retired two units whose exhausts were visibly the worst offenders.
Scenario 2: Shisha lounge compliance, Riyadh, Saudi Arabia. A chain of 12 shisha lounges in Riyadh faced Civil Defence inspection with a ventilation requirement and no instrumentation to prove it. Each lounge received three CO560 detectors at breathing height in the seating zones, interfaced to the existing extraction fan panel through the relay stages, so the CO trend itself drives ventilation rather than a wall switch an employee forgets at opening. The Civil Defence submission included the NIST-traceable calibration certificates per unit and the SABER documentation for the shipment. Within the first month the data showed that Thursday and Friday evenings peaked near 90 ppm with the old fan settings, above any acceptable occupational band for staff working full shifts, and the fan speed curve was retuned twice from the same data series until the peak sat under 25 ppm.
Scenario 3: Ski chalet fleet, Tyrol, Austria. A chalet operator above Innsbruck had a flue blocked by wind-driven snow at 1,800 m, with guests asleep in the loft bedroom directly under the wood-stove flue run. The retrofit put a CO210 voice announcement build in every sleeping room and one beside each stove, because a voice message wakes sleeping guests more reliably than a tone alone and the accessory strobe jack covers the one hearing-impaired regular guest. The wide-temperature behaviour of the sealed cell was the deciding specification over cheaper replaceable-cell units, since chalets are heated only when let, and the alarms cycle between minus 20 deg C empty and plus 24 deg C occupied all season. Fourteen chalets were equipped before the season, and the operator credits the pre-alert stage with one flue obstruction caught on the first weekend of heavy snow.
Scenario 4: Gosiwon study cubicles, Seoul, Republic of Korea. A gosiwon operator with 260 study cubicles, each barely larger than a bed, shares gas water heaters that serve the shower rooms down the corridor. The fire service inspection required CO detection in the water-heater plant room and the corridor sleeping zone. The CO210 units were mounted mid-wall in the corridors rather than at the ceiling, because the tiny room volumes and door-closed sleeping pattern stratify CO along the corridor axis, and the interconnect variant makes the plant room and corridor alarms sound as one group. The installation took a single evening shift with no drilling into the pre-fab partitions, using the adhesive mount option on the twist plates, and the audit passed with the per-room placement photographs attached to the fire service file.
Scenario 5: High-altitude guesthouse rooms, Cusco, Peru. At 3,400 m, combustion appliances burn inefficiently and guests already arrive with altitude headaches, which masks the early CO symptoms entirely. A guesthouse group fitted the CO330 with the digital display in every room with a gas heater, partly for protection and partly as a guest-facing reassurance, because a visible 0 ppm reading next to the heater settles the recurring complaint about stuffiness that the front desk used to field nightly. The peak memory function caught one heater with a badly adjusted air shutter that crept to sustained 40 ppm overnight without ever reaching an alarm stage, and the display trend convinced the owner to replace the unit rather than argue with the technician. Sixty-eight rooms were equipped, and the ppm logs now accompany the annual gas service visit.
Wanlin Competitive Advantages for Cross-Border Carbon Monoxide Alarm Buyers
The WANLIN-340 Wireless Heat Detector with Rate-of-Rise and Fixed Temperature Element and the wider Wanlin carbon monoxide alarm programme deliver 10 distinct advantages for cross-border B2B buyers who source CO detection hardware directly from a Chinese manufacturer:
- Source-factory pricing - Wanlin operates the SMT lines, the cell calibration benches and the CO test gas chambers, so FOB Shenzhen CO alarm pricing is 40-60% below Kidde, First Alert, BRK, X-Sense, Ei Electronics, Aico, FireAngel, Honeywell, Bosch or Siemens distribution prices for the same documented EN 50291 or UL 2034 scope.
- Full type-test documentation - every CO alarm family ships with the EN 50291-1 and EN 50291-2 or UL 2034 test report reference, the declaration of conformity, the radio type-approval reference and the per-unit calibration record where applicable, removing the largest documentation blocker for importers and tender bidders.
- One platform, many national conformity routes - CE and UKCA for Europe, UL 2034 and ULC for North America, INMETRO for Brazil, BIS for India, SIRIM for Malaysia, TISI for Thailand, SNI for Indonesia, DTI-BPS for the Philippines, NOM for Mexico, KC for Korea, SASO and SABER for Saudi Arabia, EAC for the Eurasian route, SABS for South Africa, CCCF for China and ActivFire for Australia, documented per SKU so the authority submittal and the approval review in each destination market complete in weeks rather than months.
- Sealed 10-year build for portfolio owners - the WANLIN-CO210 has no battery door at all, which removes battery replacement labour, nuisance chirp complaints and the compliance gap after a tenant removes a cell, and presents a single tamper-resistant housing at every inspection photograph.
- Two-stage industrial fan control - the WANLIN-CO560 reads the deck at bird or breathing height, drives ventilation at the 25 ppm stage, forces full extraction at the 200 ppm stage, and logs the ppm curve that proves the air quality case to the concession authority or the insurer.
- Four radios on one mechanical platform - 433 MHz interconnect with no recurring fee for group alarms, LoRaWAN where hundreds of devices sit behind one gateway, NB-IoT or 4G LTE Cat-1 for dispersed single points and sites with no broadband at all, Wi-Fi only where IT approves it in writing, and RS485 Modbus RTU where the fan controller is the integration point, chosen per building with the lifetime connectivity cost quoted before commitment.
- Placement engineering included - CO density tracks air, so EN 50292 placement logic follows airflow and the sleeper rather than a fixed height rule; our project documentation records per-unit placement photographs and the reasoning, which is exactly what acceptance inspections and insurance surveys ask for.
- Project-specific ODM depth - housing artwork and colour, voice announcement languages for local markets, strobe and bed-shaker accessory integration for hearing-impaired occupants, marine gasketed builds for salt air, wide-temperature cells for winter storage and arctic camps, retailer-ready packaging, and Arabic, Spanish, Portuguese, Korean, Turkish, Polish, German, French or destination-language manuals, engineered from one factory.
- Complete CO programme from one factory - sealed CO alarms, smart LCD CO alarms, industrial two-stage CO detectors, multi-parameter hazard nodes, combination-class detectors, sounder strobes, panels, gateways, gas detectors and the A119-YW test tool, all shipped together from one Shenzhen source with one set of declarations.
- Warranty up to 60 months - 60 months for the sealed CO alarm and IoT detector families, 36 months for the industrial CO detector, panel and gateway families, 24 months for instrumentation and tester families, with free DOA replacement within 60 days.
Combined, these advantages allow Wanlin partners to win landlord compliance programmes, hotel and hostel standardisation, parking concession bids, caravan and marine factory-fit contracts, senior living and student housing rollouts, fuel forecourt and retail chain standards, and national distributor frameworks, secure regional distribution rights and serve end customers under their own brand at 40-60% lower landed cost compared to legacy western retail-chain channels.
Certifications, Standards Route and Market Access Compliance
The WANLIN-340 Wireless Heat Detector with Rate-of-Rise and Fixed Temperature Element carries the following certifications as standard scope: EN 54-5 / CE / RoHS / REACH / FCC Part 15 / GB 4716 CCCF / IP65 ingress test report. Optional add-on documentation available on request includes VdS (Germany), LPCB (United Kingdom), ETL and FM (global insurance), UL 2034 and ULC listing (North America), ActivFire (Australia), CNBOP-PIB (Poland), ATEX and IECEx for hazardous-area devices, KC (Korea), NOM (Mexico), SASO and SABER (Saudi Arabia), and radio type-approval reports per destination for the 433 MHz, LoRaWAN, NB-IoT, LTE and Wi-Fi models. All devices are produced in an ISO 9001:2015 and ISO 14001:2015 certified factory with RoHS and REACH declarations issued per batch.
Cross-border buyers should note that CO alarm equipment sits across four compliance legs: the device standard such as EN 50291-1, EN 50291-2 or UL 2034, the radio type-approval for connected models in the destination band plan, the installation and placement practice such as EN 50292, NFPA 720 or the local gas safety rules where the device is documented as part of a building system, and the destination conformity route plus environmental declarations. Wanlin supplies a pre-validated compliance pack per model covering DoC templates, type-test references, radio approvals, calibration records and the annual self-test survey template, which typically moves importer approval from a quoted 8-14 weeks down to 2-4 weeks for most markets. What stays local is the installation licence, the acceptance by your authority and any civil work - Wanlin does not contract abroad and does not present itself as a licensed installer in your city.
Order Economics, MOQ, Lead Time and Logistics Math
For a typical first-time buyer ordering 5000 pieces of WANLIN-340 Wireless Heat Detector with Rate-of-Rise and Fixed Temperature Element, the economics stack is:
| Cost Layer | USD per piece | USD for 5000 pcs |
|---|---|---|
| FOB Shenzhen factory price | $17.50 | $87,500.00 |
| + Sea freight FCL 40HQ (estimated) | $3.15 | $15,750.00 |
| CIF destination port | $20.65 | $103,250.00 |
| + Customs duty 3-10% (region dependent) | $1.23 | $6,150.00 |
| + Local delivery + warehousing | $6.56 | $32,800.00 |
| DDP landed cost | $28.44 | $142,200.00 |
Sample order cost is USD 120 per SKU refundable against the first bulk order above MOQ. 30% T/T deposit and 70% balance against B/L copy is the standard payment term. L/C at sight is accepted for orders above USD 80,000. Production lead time is 18-25 days. Warranty is 60 months. Free DOA replacement within 60 days of receipt.
Carbon Monoxide Alarm FAQ - Standards, Placement, Power, Radios, False Alarms and Terms
Below are 8 frequently asked questions from overseas buyers, cross-border trading companies and regional distributors sourcing carbon monoxide alarms and CO detection hardware from China. Each answer is anchored on Wanlin actual commercial terms, certification scope and field experience across 60+ export markets under the Wanlin brand.
Should I buy EN 50291 or UL 2034 carbon monoxide alarms, and what is the difference?
Answer: EN 50291 is the European residential CO alarm standard and UL 2034 is the North American one, and the difference is mostly the time-weighted response envelope rather than the hardware. Both require the alarm to respond faster as concentration rises: roughly 50 ppm within 60-90 minutes, 100 ppm within 10-40 minutes and 300 ppm within 3 minutes in EN 50291-1, with UL 2034 in the same family of time limits. The CO210 and CO330 families are engineered against the EN 50291-1 envelope as standard scope with UL 2034 documentation available as an add-on scope, so the same platform serves both routes. What you must not do is ship the wrong documentation for the destination: the declaration of conformity, the type-test report and the radio type-approval for wireless models all travel per SKU and per shipment. Our engineers confirm the destination market and the applicable scheme before quoting, because that answer decides the documentation pack and sometimes the housing or marking variant.
Where should a carbon monoxide alarm be mounted, and does height matter like it does for smoke?
Answer: CO has almost the same density as air at room temperature, so it neither pools at the floor like LPG nor rises straight to the ceiling like hot smoke, and placement follows airflow and the appliance rather than a fixed height rule. EN 50292 practice puts the alarm at breathing height in the same room as the appliance, on a wall rather than cramped in a corner, away from windows, vents and dead-air spaces, and in rooms where people sleep when the appliance serves those rooms. In practice our project teams mount at 1.5 m on the wall in the appliance room, mid-wall in corridors, and at breathing height in sleeping rooms, and we document the placement photographs per unit because the acceptance inspection asks for them. In boats, caravans and small cabins the same logic holds: read the average concentration where the sleeper breathes, not a pocket near the exhaust.
Sealed 10-year battery, replaceable battery or mains power, which should a portfolio owner choose?
Answer: The sealed build wins almost every landlord and operator argument, and the reasoning is operational rather than electrical. Replaceable-cell alarms generate three recurring costs: battery replacement labour or shipping, nuisance chirps that arrive as complaints at unsociable hours, and the compliance gap in the window after a tenant removes a cell. The CO210 sealed 10-year build has no battery door, presents a single tamper-resistant housing at inspection, and removes the entire battery line from the maintenance budget. Mains-powered units like the CO330 suit plant rooms and commercial sites where wiring exists and a display adds value, and the sealed backup cell keeps full alarm function through outages. We quote both with the 10-year total cost side by side, and in our experience the sealed build is cheaper from year three onward once service visits are counted.
Which radio should a connected CO deployment use, and who pays the recurring cost?
Answer: The radio is chosen per building, not per project. Wi-Fi suits sites with an approved guest or IoT VLAN and no recurring fee, and it is the fastest to commission. NB-IoT suits dispersed single points like plant cupboards with no local network, with the lowest power draw and years of battery life. 4G LTE Cat-1 suits sites with no broadband at all, such as generator compounds and remote camps, with the widest roaming. LoRaWAN suits dense campus rollouts where hundreds of devices sit behind one gateway, and the RS485 Modbus wired build on the CO560 suits parking decks and tunnels where the fan controller integration is the point and cabling already runs. The recurring cost question decides more of these choices than the radio specification, so we quote every option with its lifetime connectivity cost before you commit, including the on-premise-only route where policy demands no cloud dependency at all.
How do you handle false alarms and cross-sensitivity, especially hydrogen from charging rooms?
Answer: Electrochemical CO cells cross-react with hydrogen, and a CO alarm mounted beside a lead-acid charging bank will read the hydrogen as CO, which is why placement guidance excludes charging rooms and battery halls from standard CO alarm positions. The CO210 and CO330 cells carry a hydrogen cross-sensitivity compensation circuit, and the CO560 industrial build offers the placement separation plus threshold staging that a parking deck or plant room needs. Solvent and silicone vapours during building works are the other classic nuisance source, and the documented answer is the same for every fleet we ship: thresholds are confirmed remotely and logged, the ppm trend is the evidence for every adjustment, and the first month of real data tunes the site profile before the handover signature. An alarm that nuisance-trips destroys trust faster than one that is slightly late, so the tuning month is part of the standard project scope, not an optional extra.
Combination smoke and CO alarm, or separate devices, and why does it matter for tenders?
Answer: Combination devices like the WANLIN-303 family reduce ceiling clutter and cost per protected room, and they are the right answer for bedrooms, hallways and rental units where the procurement argument is coverage per dollar. Separate devices win where the smoke and CO risks live in different rooms, where the maintenance replacement cycles differ, or where the tender specification names both device classes separately, which is common in public procurement. There is also a lifecycle argument: a CO cell reaches end of life on its own 10-year clock even when the smoke chamber is still healthy, and in a combination unit that retires the whole device, while separate units retire independently. We publish both routes with the same documentation scope and let the placement plan decide, because the correct answer is a room-by-room decision rather than a project-wide one.
What certification scope ships with the equipment, and what stays local?
Answer: Standard scope per SKU is EN 50291-1 and EN 50291-2 documentation with CE, RoHS and REACH declarations, radio type-approval for the wireless variants, GB 15322 CCCF references for the China scheme, and UL 2034 documentation as an add-on scope for North American destinations. Factory scope is ISO 9001 and ISO 14001 with RoHS and REACH declarations per batch. Destination-specific documentation such as UKCA, SASO and SABER, EAC, BIS, SIRIM, TISI, SNI, DTI-BPS, NOM, INMETRO and KC is prepared per destination and per shipment, and the NIST-traceable calibration certificate ships per unit on the CO560 industrial family. What stays local is installation licensing, authority acceptance and any civil work: Wanlin does not contract abroad and does not present itself as a licensed installer in your country, and we say so plainly rather than leave the impression otherwise.
What are the MOQ, lead time, sample and payment terms for a first order?
Answer: MOQ ranges from 200 pieces on the industrial CO560 family and 300 on the smart CO330 to 1,000 pieces on the high-volume sealed CO210, with mixed-SKU containers accepted on a first order. Standard lead time is 15-28 days depending on model and certification scope. Samples ship in 3-7 days by express for stock SKUs and 7-15 days for special configurations, with sample cost refundable against the first bulk order above MOQ. Standard terms are 30 percent T/T deposit with the balance against bill of lading copy, and L/C at sight is accepted above USD 80,000. Three partnership tiers exist, Authorized Reseller, Regional Distributor and Strategic OEM, each with documented annual volume, discount, exclusivity and joint marketing terms rather than negotiated case by case.
Wanlin Global Partner Stories - Real CO Alarm Project References across 60+ Markets
Wanlin carbon monoxide alarm programmes have shipped to 60+ markets across 6 continents, with the United Kingdom, the United States, Germany, Australia, Spain, Indonesia, Nigeria, Saudi Arabia, Poland, Canada, Chile, Japan, Qatar, Portugal, France, Turkiye, South Africa, Thailand, the Philippines, Colombia, Hungary and the United Arab Emirates among the most active sourcing routes. Below are 4 anonymised project references drawn from 2023-2026 deployments. Each record states what the earlier arrangement was, what was actually installed, and what was measured or agreed afterwards, rather than restating a capability claim.
Case 1: Madrid parking operator retrofits 11 decks with two-stage fan control. A parking operator managing 11 decks totalling 7,800 spaces replaced timer-driven ventilation with a 214-detector WANLIN-CO560 grid across two concessions in the Madrid city programme. The RS485 Modbus RTU daisy chain integrated with the existing fan controllers through the relay stages, with stage one at 25 ppm and stage two at 200 ppm. Commissioning ran deck by deck across nine weeks with zero closure days. The measured fan runtime dropped from 21 hours per day to 5.1, and the operator credits the ppm trend data with winning the renewal concession bid, because the submittal included a year of documented air quality evidence no competing bidder could produce.
Case 2: Budapest hotel group standardises boiler-room CO monitoring across 14 properties. A hotel group with 14 properties in Budapest and regional cities put the WANLIN-CO330 into every boiler room, laundry plant and pool plant room under one cloud account with per-property event history. The insurer survey that triggered the programme accepted the monthly ppm export as the documented monitoring evidence. First order 420 units mixed Wi-Fi and 4G variants, delivered in 22 days with CE and radio type-approval documentation per SKU. In the first heating season the platform flagged a slowly sooting flue in one property whose weekly peak climbed 6 ppm per month for four months, and the repair was completed before the peak season at a third of the cost of the previous year emergency call-out on the same boiler.
Case 3: Accra estate manager equips 38 generator sheds on 4G with no site broadband. An estate facilities company in Accra equipped 38 diesel generator sheds with the WANLIN-CO330 4G LTE Cat-1 variant, each shed reporting independently over cellular because the estate has no shared network. Alarm escalation lands as SMS and voice call to the duty manager, with a weekly ppm summary circulated to the estate committee. The first container 120 units including sealed CO210 units for guard rest areas, delivered in 26 days. The first month of data forced the relocation of two guard rest bunks sharing rooms with generators, and the ppm curve now accompanies every generator service record, which the company credits with ending a long-running argument with the maintenance contractor about which exhausts were the worst offenders.
Case 4: Lower Saxony caravan manufacturer offers sealed CO alarms as standard fit. A caravan manufacturer in Lower Saxony made the WANLIN-CO210 a standard fit in every 2026 model with an LPG appliance, after two seasons of dealer-fitted retail alarms producing battery complaints from seasonal customers. The sealed build ends the winter storage argument entirely, because a caravan that sits unheated from November to March still presents a green power LED at the first spring let. Annual volume 9,500 units across four model lines, with EN 50291 documentation and a dealer fitting card per unit. The manufacturer marketing team made the 10-year sealed cell a headline line in the 2026 brochure, and the dealer network reported the CO alarm complaint category dropped out of the warranty top ten within one season.
Partnership Models - Project Supply, Authorized Reseller, Regional Distributor, Strategic OEM
Wanlin offers 3 partnership tiers for cross-border carbon monoxide alarm buyers, landlord portfolio operators, parking and facility operators, contractors and overseas cooperation partners:
| Tier | Annual Volume | Discount | Exclusivity | Support |
|---|---|---|---|---|
| Authorized Reseller | USD 30,000+ | 0% (list price) | No | Standard warranty per family |
| Regional Distributor | USD 100,000+ | 22% off list | Single country | Co-marketing USD 6,000/year, joint certification cost-share |
| Strategic OEM Partner | USD 320,000+ | 32% off list | Multi-country | Dedicated engineering team, joint roadmap, 18-month price lock |
All partners receive: free firmware updates for life of product, free DOA replacement within 60 days, dedicated account manager and response within 4 business hours, free certification documentation and test report copies, destination-language manual support, placement engineering guidance per project, integration assistance including MQTT topic structure and Modbus register maps for partners running their own servers, and one joint trade-show booth per year at Intersec Dubai, Security Essen, NFPA Conference, Firex International, Secutech, SICUR, FeuerTrutz, FireExpo or Canton Fair on a cost-share basis.
Conclusion - How to Start Your Carbon Monoxide Alarm Sourcing Today
Wanlin Group 2026 carbon monoxide alarm export program is now open for global B2B buyers, regional distributors, housing associations and letting agents, senior living and student housing operators, hotel and hostel chains, parking and tunnel operators, marina and caravan dealers, HVAC contractors, facility management contractors, insurers, cross-border trading companies and OEM and ODM partners across 60+ destination markets. To initiate a sourcing discussion, request a quotation or schedule a factory audit in Shenzhen, please contact our export team via the channels below. Sample orders ship within 3-7 days via DHL Express for in-stock SKUs; custom-configuration samples require 7-15 days. Standard lead time for bulk OEM orders is 18-25 days. Strategic OEM Partner applications are reviewed quarterly and require a minimum USD 320,000 annual commitment.
We sincerely invite global safety equipment buyers, national importers, tender bidders, landlord portfolio managers, hotel and resort groups, parking and tunnel operators, marina, caravan and RV manufacturers, senior living and student housing operators, fuel forecourt and retail chains, system integrators and cross-border trading companies to engage in long-term cooperation with Wanlin Group as your China-based OEM and ODM partner, regional exclusive distributor or strategic global supplier under the Wanlin brand. Wanlin is the Chinese source factory behind 60+ country CO detection programmes, the SMT lines, cell calibration benches and CO test gas chambers behind every batch, and this 12-section export program. Let us protect every sleeper together.
Article signature:
working_principle: Rate-of-rise plus fixed temperature dual algorithm evaluated on a thermistor bridge with air-flow compensation sensing_element: NTC thermistor with a stainless-steel heat collector, A1R / A2S / BR / CS class selectable per SKU alarm_threshold: Fixed temperature 54-70 deg C by class, rate-of-rise trip between 3 and 30 deg C/min accuracy_class: EN 54-5 and GB 4716 class accuracy, thermistor tolerance +/-1.5 deg C, rate-of-rise window selectable in three bands response_time: Static response within 30-120 s to the EN 54-5 test regime by class, rate-of-rise trip within 60 s of a fast transient power_supply: 3.6V ER18505M lithium cell, 5-year service life, field-replaceable, 3-year life on the 4G SKU power_consumption: 11 uA standby, 120 mA peak transmit, 28 mA in alarm output_signal: 433 MHz FSK uplink to the 860 panel or the 868D gateway with a 24 h supervisory heartbeat coverage_area: Up to 50 m2 at 6 m mounting height, 30 m2 in high-ceiling or high-airflow areas alarm_output: Integral 80 dB(A) at 3 m sounder plus platform alert and group alarm through the paired gateway ip_rating: IP65 sealed polycarbonate housing for wash-down kitchens and food plants operating_temp: -30 deg C to +70 deg C industrial wide-temp for cold stores, kilns and unheated plant humidity_range: 10-95% RH non-condensing, conformal-coated PCB on the IP65 SKU housing_material: Polycarbonate V-0 housing with a 316 stainless-steel heat collector and a gasketed base dimensions_weight: 100 mm diameter x 46 mm height, 152 g net including the cell certifications: EN 54-5 / CE / RoHS / REACH / FCC Part 15 / GB 4716 CCCF / IP65 ingress test report
- Author: Wanlin Group Fire Detection Division Export Engineering Team
- Published: 2026-09-22 16:19
- Data sources: Wanlin Group 2026 carbon monoxide alarm export programme documentation, electrochemical cell calibration records per production lot, EN 50291-1 and EN 50291-2 type-test references, UL 2034 documentation scope, radio type-approval records for the 433 MHz, LoRaWAN, NB-IoT, LTE and Wi-Fi models, ppm trend and false-alarm statistics from deployed landlord, hotel, parking, marine and plant-room sites, integration records covering Modbus, BACnet IP, MQTT and fan-control deployments, installation and self-test logs from partner projects, RoHS, REACH and WEEE declarations.
- Shenzhen HQ: Wanlin Group (Wanlin Fire Detection Division), Building B, Building 1, Beisida Medical Device Building, 28 Nantong Avenue, Baolong Community, Baolong Sub-district, Longgang District, Shenzhen, Guangdong, China
- Reference: www.wanlinfire.com / WANLIN-340 / EN 50291-1 / EN 50291-2 / EN 50292 / UL 2034 / UL 2075 / NFPA 720 / NFPA 72 / GB 15322 / EN 50194 / EN 54 / RoHS REACH WEEE
- Contact: Email wanlinfirecontrol@163.com | Phone +8613261677119 | Website https://www.wanlinfire.com